Catalog

HomeProductsPower CablesRubber CableYq/Yqw/Yz/Yzw/Yc/Ycw 450/750V 0.3-150mm² 2-5cores Waterproof Flame-Retardant Heavy duty Rubber Sheathed Power Cable and Wires

Yq/Yqw/Yz/Yzw/Yc/Ycw 450/750V 0.3-150mm² 2-5cores Waterproof Flame-Retardant Heavy duty Rubber Sheathed Power Cable and Wires

Rubber insulated wires and cables of suitable for power device with moving installation and rated voltage up to and including 450/750V.

Share:

Structure

Description

Product Description

Universal rubber sheathed cable is applicable to movable electrical equipment, electric tools, instruments and household appliances as power supply; It is the most widely used rubber sheathed flexible cable with the largest output. It is made of thin diameter copper single wire with multiple strands bundled, twisted into a conductor, then extruded and wrapped with rubber insulation layer, after vulcanization, stranded into a cable, and then extruded and wrapped with rubber sheath and vulcanized.
General rubber sheathed cables are divided into light (YQ and YQW), medium (YZ and YZW) and heavy (YC and YCW) types according to mechanical performance requirements, and each type is divided into general type and outdoor (weather resistant) type.
The general rubber sheathed cable is often moved and bent in use, and it is required to be soft. Due to frequent contact with human body, it is required to have excellent electrical performance, reliable operation and be able to withstand different mechanical external forces. Weather resistant cable shall have good weather resistance and certain oil resistance.
YQ and YQW light rubber sheathed cables are required to have excellent flexibility, which is conducive to multiple non directional bending. The cables themselves are not twisted, light, small in outer diameter, and half of them do not directly bear external mechanical forces. It is applicable to the power cord of household appliances and instruments.
YZ and YZW medium rubber sheathed cables shall be flexible enough to move, bend and withstand general mechanical external forces. It is suitable for agricultural mobile power line and power line of electric tools.

Product technical parameters

1.1 Rubber insulated wires and cables of suitable for power device with moving installation and rated voltage up to and including 450/750V.

Model Name Usage
YQ.YQW Light-Duty flexible rubber cable   Used for light-duty moveable electrical equipment and tools
60245IEC53(YZ),
60245IEC57(YZW)
Ordinary flexible rubber cable   Used for moveable electrical equipment and tools
YZ,YZW Medium-Duty flexible rubber cable   Used for moveable electrical equipment and tools
60245IEC66(YCW).YC.YCW Heavy-Duty flexible rubber cable   Used for moveable electrical equipment and can withstand
  bigger mechanical force

2.1 Rated power-frequency voltage Uo/U:450/750V and 300/500V and 300/300V.
2.2 Max.admissible operating temperature of the conductor:60℃ .
2.3"W'type rubber cable have the capacity to withstand weather,oils/greases,suitable for use in outdoor and oil environment.

     The cable's conductor construction and electric resistance
Nominal cross
sectional  area(mm³)

Construction

20℃Conductor direct current
electric resistance(Ω/km)
Nominal cross
sectional  area(mm²)

Construction

20℃Conductor direct current
electric resistance(Ω/km)
0.3  16/0.15 ≤69.2 16  126/0.40 ≤1.21
0.5  28/0.15 ≤39.0 25  196/0.40 ≤0.780
0.75  24/0.20 ≤26.0 35  276/0.40 ≤0.554
1.0  32/0.20 ≤19.5 50  396/0.40 ≤0.386
1.5  48/0.20 ≤13.3 70  360/0.50 ≤0.272
2.5  49/0.25 ≤7.98 95  475/0.50 ≤0.206
56/0.30 ≤4.95 120  608/0.50 ≤0.161
84/0.30 ≤3.30 150  756/0.50 ≤0.129
10  84/0.40 ≤1.91      
No.of Cores×Nominal Cross
Sectional Area mm²
Nominal Thickness of
Insulation(mm)
Nominal Thickness
of Sheath(mm)
Average Overall
Diameter(mm)
Reference Weight
(kg/km)
Min    Max YQ YQW
2×0.3 0.5  0.7  4.3  5.8  40  48 
2×0.5 0.5  0.7  4.8  6.4  49  59 
3×0.3 0.5  0.7  4.6  6.1  57  68 
3×0.5 0.5  0.7  5.1  6.7  69  83 
60245IEC53(YZ),60245IEC57(YZW),YZ,YZW300/500V
Nominal cross
sectional
area(mm)
Nominal Thickness
of Insulation(mm)
Tow cores   Three cores
Nominal Thickness
of Sheath(mm)
Average Overall
Diameter(mm)
Reference
Weight(Kg/km)
Nominal Thickness
of Sheath(mm)
Average Overall
Diameter(mm)
Reference
Weight(kg/km)
Min Max YZ YZW Min Max YZ YZW
0.75  0.6  0.8  5.7  7.4  70  84  0.9  6.2  8.1  85  102 
1.0  0.6  0.9  6.1  8.0  84  101  0.9  6.5  8.5  105  120 
1.5  0.8  1.0  7.6  9.8  110  130  1.1  8.0  10.4  136  155 
2.5  0.9  1.1  9.0  11.6  153  183  1.2  9.6  12.4  194  228 
1.0  1.2  10.6  13.7  234  260  1.3  11.3  14.5  287  320 
1.0  1.3  11.8  15.1  312  375  1.4  12.6  16.1  385  430 
                       
Nominal cross
sectional  area(mm²)
Nominal Thickness
of Insulation (mm)
Four cores
Nominal Thickness
of Sheath(mm)
Average Overall
Diameter(mm)
Reference Weight
(kg/km)
Min    Max YZ YZW
0.75  0.6  0.9  6.8  8.8  116  139 
1.0  0.6  0.9  7.1  9.3  125  150 
1.5  0.8  1.1  9.0  11.6  180  210 
2.5  0.9  1.2  10.7  13.8  242  280 
1.0  1.3  12.7  16.2  396  430 
1.0  1.4  14.0  17.9  530  570 
             
Nominal cross
sectional area(mm)
Nominal Thickness
  of Insulation (mm)
(3+1)Four  cores(3+1)
Main CorexSection
+Earth Core
×Section(mm²)
Nominal Thickness
of Sheath(mm)
Average Overall
Diameter(mm)
Reference Weight
(kg/km)
  Min  Max YZ YZW
0.75  0.6  -
1.0  0.6    -      
1.5  0.8  3×1.5+1×1 1.1  8.6  11.2  171  188 
2.5  0.9  3×2.5+1×1.5 1.2  10.4  13.3  232  260 
1.0  3×4+1×2.5 1.3  12.3  15.7  375  392 
1.0  3×6+1×4 1.4  13.7  17.5  485  520 