Catalog

HomeProductsPower CablesLow Voltage Power CableFactory Bulk Supply XLPE Insulated PVC Sheathed 06/1kV Low Voltage Power Cable for Industrial Marine Overhead Computer

Factory Bulk Supply XLPE Insulated PVC Sheathed 06/1kV Low Voltage Power Cable for Industrial Marine Overhead Computer

Our XLPE Insulated PVC Sheathed Power Cable (0.6/1kV, 450/750V) is designed for superior electrical performance, safety, and durability in demanding environments.

Share:

Structure

Description

Application
Cross-linked polyethylene insulated power cables is characterized with high mechanical   strength,strong   resistance to environmental stress,excellent electrical properties ,powerful resistance to chemical attack.In addition,the light and simple products are user-friendly.This product is suitable and   designed   for power transmission and distribution system of rated voltage 0.6/1kv.In terms of the main feature of anti-flaming cable,the cable is not liable to continued ignition is only  limited to a certain scope applicable to power station ,subway ,tunnel ,high-rise building,large industrial and mining enterprise,oil field,coal mine and other places of intensive distributed electric cables.
Main Characteristics

What is the difference between YJV and YJV-22 cables?

yjv cable vs yjv-22

Structure and application:
YJV cables are made of cross-linked polyethylene (XLPE) insulation and PVC sheaths. yjv is suitable for indoor use with very low risk of mechanical damage. yjv-22 cables have a metal armor in addition to the same insulation and sheath. This makes it ideal for underground or external installations that are susceptible to mechanical stress.

Resistance and protection:
YJV cables have excellent electrical insulation, mechanical protection and environmental resistance. It is well suited for environments with low physical requirements. YJV-22 cable is armored with steel tape. It has excellent resistance to impact and extrusion and is suitable for industrial environments and areas with physical disturbances.

Selection Criteria:
The choice between YJV and YJV-22 cables depends on environmental conditions and mechanical stress; YJV cables are best suited for protected indoor environments, while YJV-22 cables are suitable for outdoor or underground environments where the risk of physical damage is high.

YJV Cable Conclusion
An explanation of the field of YJV cables reveals their importance in a variety of environments, from residential to industrial applications. We dissect the structure, applications, and key differences between yjv cables and yjv22. We believe we have come to this point with a clearer understanding of cable selection. In the meantime, if you want to go further to get a comprehensive cable solution or obtain yjv series cables price, xijiangyue Cable manufacturer offers you a way to get quality products

Multiple models and specifications

XLPE INSULATED LV ARMORED POWER CABLES

1. Scope
(1) Operating temperature: Maximum continuous conductor temperature: 90°C
(2) Short-circuit temperature: 250°C (max. duration 5 seconds)
(3) Bending radius:
- Single-core cable: 12×D
- Multi-core cable: 10×D
D = Cable overall diameter (mm)
(4) Installation temperature: Minimum laying temperature: -5°C
(5) Current rating parameters:
- Ambient temperature (air): 40°C
- Ambient temperature (burial): 25°C
- Soil thermal resistivity: 1.5 K·m/W

2. Construction
(1) Conductor: Stranded copper (Class 2)
(2) Insulation: XLPE
(3) Sheath: LSZH termite resistant
(4) Standards: IEC 60502-1, IEC 60332-1-2
(5) Voltage rating: 0.6/1 kV

Specification

Table 1 Single core CU/PVC/PVC IEC 60502-1

No. of cores Approx. diameter of conductor Nominal thickness of insulation Nominal diameter of armor wire Nominal thickness of outer sheath Approx. OD of cable Approx. weight of cable
& CSA
  Phase Earth Phase Earth
  mm mm mm mm mm mm mm kg/km
1C1.5 1.56 / 0.7 / 0.8 1.4 10 123
1C2.5 2.04 / 0.7 / 0.8 1.4 10.5 140
1C4 2.55 / 0.7 / 0.8 1.4 11 163
1C6 3.1 / 0.7 / 0.8 1.4 11.6 191
1C10 4 / 0.7 / 0.8 1.4 12.5 242
1C16 5 / 0.7 / 0.8 1.4 13.5 313
1C25 6.1 / 0.9 / 0.8 1.4 15 425
1C35 7.2 / 0.9 / 0.8 1.4 16.1 530
1C50 8.4 / 1 / 1.25 1.5 18.6 723
1C70 10 / 1.1 / 1.25 1.5 20.4 951
1C95 12 / 1.1 / 1.25 1.6 22.6 1241
1C120 13 / 1.2 / 1.6 1.7 24.7 1553
1C150 14.9 / 1.4 / 1.6 1.7 27 1868
1C185 16.5 / 1.6 / 1.6 1.8 29.3 2264
1C240 18.4 / 1.7 / 1.6 1.9 31.6 2856
1C300 21 / 1.8 / 1.6 1.9 34.4 3480
1C400 23.4 / 2 / 2 2.1 38.8 4506
1C500 26.6 / 2.2 / 2 2.2 42.6 5632
1C630 30 / 2.4 / 2 2.3 46.6 7049
1C800 34 / 2.6 / 2.5 2.5 52.9 9072

Table 2 Two core CU/PVC/PVC IEC 60502-1

No. of cores Approx. diameter of conductor Nominal thickness of insulation Nominal diameter of armor wire Nominal thickness of outer sheath Approx. OD of cable Approx. weight of cable
& CSA
  Phase Earth Phase Earth
  mm mm mm mm mm mm mm kg/km
2C1.5 1.56 / 0.7 / 0.8 1.8 14.5 326
2C2.5 2.04 / 0.7 / 0.8 1.8 15.4 378
2C4 2.55 / 0.7 / 0.8 1.8 16.4 440
2C6 3.1 / 0.7 / 0.8 1.8 17.5 513
2C10 4 / 0.7 / 1.25 1.8 20.2 775
2C16 5 / 0.7 / 1.25 1.8 22.2 970
2C25 6.1 / 0.9 / 1.6 1.8 26 1426
2C35 7.2 / 0.9 / 1.6 1.8 28.2 1712
2C50 8.4 / 1 / 1.6 1.8 31 2080
2C70 10 / 1.1 / 1.6 2 35.6 2729
2C95 12 / 1.1 / 2 2.1 41 3763
2C120 13 / 1.2 / 2 2.2 43.6 4405
2C150 14.9 / 1.4 / 2 2.3 48.5 5276
2C185 16.5 / 1.6 / 2.5 2.5 54.3 6780
2C240 18.4 / 1.7 / 2.5 2.7 58.9 8244
2C300 21 / 1.8 / 2.5 2.8 65.2 9986

Table 3 Three core CU/PVC/PVC IEC 60502-1

No. of cores Approx. diameter of conductor Nominal thickness of insulation Nominal diameter of armor wire Nominal thickness of outer sheath Approx. OD of cable Approx. weight of cable
& CSA
  Phase Earth Phase Earth
  mm mm mm mm mm mm mm kg/km
3C1.5 1.56 / 0.7 / 0.8 1.8 14.9 358
3C2.5 2.04 / 0.7 / 0.8 1.8 16 420
3C4 2.55 / 0.7 / 0.8 1.8 17.1 497
3C6 3.1 / 0.7 / 0.8 1.8 18.3 594
3C10 4 / 0.7 / 1.25 1.8 21.1 900
3C16 5 / 0.7 / 1.25 1.8 23.3 1160
3C25 6.1 / 0.9 / 1.6 1.8 27.3 1708
3C35 7.2 / 0.9 / 1.6 1.8 29.6 2082
3C50 8.4 / 1 / 1.6 1.9 32.9 2594
3C70 10 / 1.1 / 2 2 38.8 3730
3C95 12 / 1.1 / 2 2.2 43.5 4771
3C120 13 / 1.2 / 2 2.3 46.3 5640
3C150 14.9 / 1.4 / 2.5 2.5 53.1 7308
3C185 16.5 / 1.6 / 2.5 2.6 57.7 8679
3C240 18.4 / 1.7 / 2.5 2.8 63.1 10766
3C300 21 / 1.8 / 2.5 3 69.5 13049

Table 4 Four core CU/PVC/PVC IEC 60502-1

No. of cores Approx. diameter of conductor Nominal thickness of insulation Nominal diameter of armor wire Nominal thickness of outer sheath Approx. OD of cable Approx. weight of cable
& CSA
  Phase Earth Phase Earth
  mm mm mm mm mm mm mm kg/km
4C1.5 1.56 / 0.7 / 0.8 1.8 15.7 400
4C2.5 2.04 / 0.7 / 0.8 1.8 16.9 474
4C4 2.55 / 0.7 / 0.8 1.8 18.1 572
4C6 3.1 / 0.7 / 1.25 1.8 20.4 830
4C10 4 / 0.7 / 1.25 1.8 22.5 1059
4C16 5 / 0.7 / 1.6 1.8 25.7 1514
4C25 6.1 / 0.9 / 1.6 1.8 29.3 2046
4C35 7.2 / 0.9 / 1.6 1.9 32.2 2545
4C50 8.4 / 1 / 1.6 2 35.8 3181
4C70 10 / 1.1 / 2 2.2 42.4 4594
4C95 12 / 1.1 / 2 2.3 47.4 5875
4C120 13 / 1.2 / 2.5 2.5 52.2 7523
4C150 14.9 / 1.4 / 2.5 2.6 58 9055
4C185 16.5 / 1.6 / 2.5 2.8 63.3 10811
4C240 18.4 / 1.7 / 2.5 3 69.2 13502
4C300 21 / 1.8 / 2.5 3.2 76.4 16386

Table 5 Five core CU/PVC/PVC IEC 60502-1

No. of cores Approx. diameter of conductor Nominal thickness of insulation Nominal diameter of armor wire Nominal thickness of outer sheath Approx. OD of cable Approx. weight of cable
& CSA
  Phase Earth Phase Earth
  mm mm mm mm mm mm mm kg/km
5C1.5 1.56 / 0.7 / 0.8 1.8 16.6 443
5C2.5 2.04 / 0.7 / 0.8 1.8 17.9 534
5C4 2.55 / 0.7 / 1.25 1.8 20.2 783
5C6 3.1 / 0.7 / 1.25 1.8 21.6 942
5C10 4 / 0.7 / 1.25 1.8 24.1 1213
5C16 5 / 0.7 / 1.6 1.8 27.5 1747
5C25 6.1 / 0.9 / 1.6 1.8 31.6 2393
5C35 7.2 / 0.9 / 1.6 1.9 34.7 3005
5C50 8.4 / 1 / 2 2.1 40.2 4110
5C70 10 / 1.1 / 2 2.3 46 5462
5C95 12 / 1.1 / 2.5 2.4 53 7540
5C120 13 / 1.2 / 2.5 2.6 56.7 8975
5C150 14.9 / 1.4 / 2.5 2.8 63.4 10872
5C185 16.5 / 1.6 / 2.5 3 69.6 13139
5C240 18.4 / 1.7 / 2.5 3.2 75.7 16346
5C300 21 / 1.8 / 3.15 3.4 85.4 20899